What was found
AFTER WIFI (FAST) INSTALL; CLOSED THE L1 DOOR FOR DEPARTURE. ON LATCHING THE DOOR, RECEIVED AN ELEC AC BUS 1 FAULT MESSAGE. UNLATCHED THE DOOR AND FAULT DISAPPEARED AND THE BUSS WAS POWERED AGAIN. REPEATED THIS 3 TIMES RECEIVING SAME SEQUENCE OF FAULT AND REPOWER OCCURRING. DISCOVERED LNK-YY22 WIRE LOCATED AT 85VU SHELF ON 1853VT BLOCK 83 PINNED AT INCORRECT LOCATION. RELOCATED LNK-YY22 FROM 1853VT BLOCK 83 POSITION L TO 1853VT BLOCK 83 POSITION M PER GOGO WIRING/INTERCONNECT DIAGRAM D12547-22302 REVISION E. OPERATIONS CHECK GOOD.