Service difficulty report · Power Supply · Airbus A319112
FAA SDR system
- Difficulty date
- June 6, 2018
- Submitted
- June 8, 2018
- Operation
- Air carrier
- Make and model
- Airbus A319112
- Aircraft serial
- 1182
- Aircraft time
- 50,426 hours, 29,578 cycles
- Part
- Power Supply
- Part number
- 32145410
- Part serial
- 2471
- Condition
- No Test
- Location
- Emergency Light
- Part time
- 47,353 hours, 30,054 cycles
- Stage of operation
- IN
- How discovered
- C
- Nature of condition
- L
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY POWER SUPPLY FAILED TO TEST. REPLACED THE POWER SUPPLY IAW AMM 33-51-38.