What was found
CRACK INDICATION FOUND ON INTERCOSTAL LEVEL DOOR STOP FITTING NR 7 AT FRAME 16, FORWARD GALLEY AREA. REPLACED THE STOP FITTING IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION FOUND ON INTERCOSTAL LEVEL DOOR STOP FITTING NR 7 AT FRAME 16, FORWARD GALLEY AREA. REPLACED THE STOP FITTING IAW SRM 51-72-11.