What was found
CORROSION ON THE FLOORBEAM AT BS 947.5, LBL 4.5 TOP SIDE. REPLACED THE FLOORBEAM IAW SRM 53-70-51-2R-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON THE FLOORBEAM AT BS 947.5, LBL 4.5 TOP SIDE. REPLACED THE FLOORBEAM IAW SRM 53-70-51-2R-5.