Service difficulty report · Actuator · Airbus A321211

Difficulty date
August 22, 2018
Submitted
August 27, 2018
Operation
Air carrier
Aircraft
N179UW
Make and model
Airbus A321211
Aircraft serial
1521
Aircraft time
58,651 hours, 21,898 cycles
Part
Actuator
Part number
HTE2000021
Part serial
39175278
Condition
Defective
Location
Control Valve
Part time
1,217 hours, 452 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE, FLIGHT FUEL CENTER RT TRANSFER FAULT MESSAGE APPEARED. REPLACED THE RIGHT JET PUMP CONTROL VALVE ACTUATOR 12QL IAW AMM 28-26-51. OPS CHECKED GOOD.