What was found
BOTTOM OF FORWARD SERVICE DOOR STUB FRAME CRACKED WHERE IT ATTACHES TO RIGHT CREASE ANGLE AT BS 294. REPAIRED THE AREA IAW SRM 51-70-11-2R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BOTTOM OF FORWARD SERVICE DOOR STUB FRAME CRACKED WHERE IT ATTACHES TO RIGHT CREASE ANGLE AT BS 294. REPAIRED THE AREA IAW SRM 51-70-11-2R.