What was found
CIDS PANEL SHOWED CAUTION, CHECK DOOR PRESSURE. THE AIRCRAFT WAS GROUNDED. MAINTENANCE FOUND THE R2 DOOR BOTTLE PRESSURE LOW, SERVICED DOOR ASSIST BOTTLE IAW AMM 52-22-00-614-002-A, AND PERFORMED SATISFACTORY OPERATIONAL CHECK. NO FAULTS NOTED.