What was found
CORROSION FOUND ON FOUR AREAS ON TOP OF THE FLOOR SUPPORT, FRAMES 16 TO 20, STRINGER 23R, Y-1292. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11-911-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FOUR AREAS ON TOP OF THE FLOOR SUPPORT, FRAMES 16 TO 20, STRINGER 23R, Y-1292. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11-911-001.