What was found
CRACKED FLOORBEAM ANGLE AT BS 540, BL 0 TO LBL 2, WATERLINE 0 TO -2. REPLACED FLOORBEAM ANGLE IAW SRM 51-10-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOORBEAM ANGLE AT BS 540, BL 0 TO LBL 2, WATERLINE 0 TO -2. REPLACED FLOORBEAM ANGLE IAW SRM 51-10-02-0G.