What was found
CORROSION ON FOUND ON THE R1 DOOR LOWER SILL CENTER FITTING BETWEEN FRAMES 16 AND 20, STRINGER 23R. REPLACED CENTER FITTING IAW SWRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FOUND ON THE R1 DOOR LOWER SILL CENTER FITTING BETWEEN FRAMES 16 AND 20, STRINGER 23R. REPLACED CENTER FITTING IAW SWRM 51-72-11.