What was found
CORROSION ON THE R1 DOOR CREASE ANGLE BETWEEN BS 296 AND 330, RBL 51. REPLACED THE ANGLE IAW SRM 51-40-02, SRM 51-40-03, DRAWING 141A8310, AND 51-00-5-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON THE R1 DOOR CREASE ANGLE BETWEEN BS 296 AND 330, RBL 51. REPLACED THE ANGLE IAW SRM 51-40-02, SRM 51-40-03, DRAWING 141A8310, AND 51-00-5-1.