What was found
CRACKED INTERCOSTAL FITTING AT THE R1 DOOR CUTOUT, AT FRAME 16, STRINGER 10R. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED INTERCOSTAL FITTING AT THE R1 DOOR CUTOUT, AT FRAME 16, STRINGER 10R. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11.