Service difficulty report · Regulator Valve · Emb ERJ190100IGW

Difficulty date
October 15, 2018
Submitted
October 17, 2018
Operation
Air carrier
Aircraft
N951UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000112
Aircraft time
24,002 hours, 19,947 cycles
Part
Regulator Valve
Part number
10012463
Part serial
2007021086
Condition
Defective
Location
Bleed Air Sys
Part time
20,078 hours, 16,338 cycles
Stage of operation
DE
How discovered
O
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED. PHL-MHT. DURING DESCENT INTO MHT FLIGHT DEVELOPED A PRESSURIZATION ISSUE. CREW DECLARED AN EMERGENCY FOR PRIORITY CLEARANCE AS A PRECAUTION. CABIN NOT PREPPED AND AFR TRUCKS DID NOT RESPOND. AIRCRAFT LANDED WITHOUT FURTHER INCIDENT. ENGINE NR 1 BLEED AIR PRESSURE WAS FLUCTUATING BETWEEN 0-60 PSI AT CLIMB POWER. THE FLIGHT DROPPED DOWN TO FL 150. THEN ENGINE NR 2 BLEED FAIL EICAS MESSAGE, WHICH WAS RESET PER QRH PROCEDURE. REPLACED HIGH PRESSURE REGULATING VALVE AND NACELLE PRESSURE REGULATING VALVE PER AMM 36-11-01/03. LEAK CHECKED PER TASK 36-11-01-790-801- / A/500. CHECK GOOD. THIS SDR IS FOR THE NACELLE PRESSURE REGULATING VALVE ON ENGINE NR 2. (SEE CONTROL AALA201810179001 AND AALA201810179002)