What was found
R2 DOOR INDICATION WAS AMBER WHEN DOOR WAS CLOSED. REPLACED THE PROXIMITY SWITCH 15WV2 IAW AMM 52-71-11-400-001-A, AND PERFORMED AN ADJUSTMENT OF THE LOCKING HOOK IAW 52-71-00-820-001-A. INDICATION ON ECAM WAS OK WHEN CLOSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R2 DOOR INDICATION WAS AMBER WHEN DOOR WAS CLOSED. REPLACED THE PROXIMITY SWITCH 15WV2 IAW AMM 52-71-11-400-001-A, AND PERFORMED AN ADJUSTMENT OF THE LOCKING HOOK IAW 52-71-00-820-001-A. INDICATION ON ECAM WAS OK WHEN CLOSED.