What was found
THERMOGRAPHIC INSPECTION REVEALED WATER INGRESS ON THE LEFT ELEVATOR UPPER SURFACE. 20.5 INCHES FROM INBOARD AND 5 INCHES FROM TRAILING EDGE. REPAIRED THE ELEVATOR IAW SRM 55-21-11-300-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THERMOGRAPHIC INSPECTION REVEALED WATER INGRESS ON THE LEFT ELEVATOR UPPER SURFACE. 20.5 INCHES FROM INBOARD AND 5 INCHES FROM TRAILING EDGE. REPAIRED THE ELEVATOR IAW SRM 55-21-11-300-005.