What was found
EMERGENCY LIGHTS CIDS PANEL FLAGING. THE EMERGENCY EXIT SIGN OVER THE L1 DOOR WAS INOPERATIVE AND 11WL BATTERY FAILED. THE AIRCRAFT WAS GROUNDED. REPLACED THE EXIT SIGN IAW AMM 33-51-38.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS CIDS PANEL FLAGING. THE EMERGENCY EXIT SIGN OVER THE L1 DOOR WAS INOPERATIVE AND 11WL BATTERY FAILED. THE AIRCRAFT WAS GROUNDED. REPLACED THE EXIT SIGN IAW AMM 33-51-38.