What was found
THE AIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHTS WILL NOT TEST OK ON CIDS PANEL. REPLACED RIGHT HAND MID EMERGENCY LIGHT POWER SUPPLY UNIT 12WL PER MM 33-51-38-0401. OPERATIONS CHECK OK.