Service difficulty report · Sensor · Airbus A319115

Difficulty date
December 7, 2018
Submitted
December 12, 2018
Operation
Air carrier
Aircraft
N4005X
Make and model
Airbus A319115
Aircraft serial
5753
Aircraft time
15,035 hours, 7,222 cycles
Part
Sensor
Part number
SEN0013
Part serial
41773
Condition
Faulty
Location
Outlet Temp
Stage of operation
CL
How discovered
O
Nature of condition
M
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ACFT RETURNED TO DEPARTURE DUE TO THE CABIN TEMPERATURE WAS UNCONTROLLABLE AND TOO HOT IN CABIN. AN EMERGENCY WAS DELCARED, AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED TSM 21-61-00, AND FOUND THE RIGHT COMPRESSOR OUTLET TEMPERATURE SENSOR AT FAULT. REPLACED THE SENSOR 32HH IAW AMM 21-61-11.