Service difficulty report · Servo Valve · Airbus A319112

Difficulty date
December 12, 2018
Submitted
December 17, 2018
Operation
Air carrier
Aircraft
N769US
Make and model
Airbus A319112
Aircraft serial
1391
Aircraft time
48,509 hours, 31,196 cycles
Part
Servo Valve
Condition
Failed
Location
Brakes
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NORMAL BRAKING AND AUTO BRAKE FAILED. REPLACED THE BRAKE SERVO VALVE 17GG IAW AMM 32-42-48-400-001-A. TESTED OK. NO LEAKS FOUND.