What was found
TRAPPED WATER INDICATION FOUND ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL. 7.75 INCHES INBD FROM LIGHTNING STRIP 3, AND 4.15 INCHES FROM THE TRAILING EDGE. REPAIRED THE ELEVATOR SKIN IAW SRM 55-21-11-300-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.