What was found
CORROSION FOUND ON THE AFT GALLEY FLOOR DECK WEB BETWEEN BS 1016 AND 1018, LBL 28. REPLACED THE WEB IAW RD 51-00-05-1, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE AFT GALLEY FLOOR DECK WEB BETWEEN BS 1016 AND 1018, LBL 28. REPLACED THE WEB IAW RD 51-00-05-1, AND SRM 51-40-02.