What was found
CORROSION FOUND ON THE GALLEY FLOOR SUPPORT ANGLE BETWEEN BS 1013 AND 1016, RBL 32. REPLACED THE FLOOR SUPPORT ANGLE IAW RD 51-00-05-1, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE GALLEY FLOOR SUPPORT ANGLE BETWEEN BS 1013 AND 1016, RBL 32. REPLACED THE FLOOR SUPPORT ANGLE IAW RD 51-00-05-1, AND SRM 51-40-02.