Service difficulty report · Safety Valve · Airbus A319132
FAA SDR system
- Difficulty date
- April 30, 2019
- Submitted
- May 2, 2019
- Operation
- Air carrier
- Make and model
- Airbus A319132
- Aircraft serial
- 1844
- Aircraft time
- 53,601 hours, 23,863 cycles
- Part
- Safety Valve
- Part number
- 90241570403
- Part serial
- 16170855
- Condition
- Unreliable
- Location
- Cabin Pressure
- Part time
- 25,044 hours, 10,066 cycles
- Stage of operation
- UK
- How discovered
- O
- Nature of condition
- J
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT WAS GROUNDED: PILOT REPORTS AIRCRAFT DEPRESSURIZED @ 5000' ON SYS 2 SAFETY VALVE & OUTFLOW BOTH AMBER AFTER DEPRESSURIZATION. MAINTENANCE REPORTS IAW TSM 21-31-00-810-808, REMOVED AND REPLACED SAFETY VALVES (6HL) & (7HL) IAW 21-31-52. OPS CHECK GOOD. SEE SDR # AALA201905029023.