What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 6.5 IN. INBOARD FROM RIB 4 AND 4 IN. FROM TRAILING EDGE ON RH HORIZONTAL STABILIZER (1 EA) L= (L = 4 IN. W = 1.6 IN. APPROX.). REPAIRED UPPER SKIN ON RH ELEVATOR HORIZONTAL STABILIZER IAW SRM A321 55-21-11-300-004.