What was found
AIRCRAFT WAS GROUNDED: PILOT DECLARED EMERGENCY ON ACCOUNT OF LEFT ENGINE BLEED FAULT INDICATION. FLIGHT LANDED OVERWEIGHT WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED PRSOV IAW AMM 36-11-09, WHILE TROUBLESHOOTING BLEED ISSUE FOUND FWD DUCT OF PRSOV DAMAGED AND LEAKING, REMOVED AND REPLACED FLEX JOINT DUCT ASSEMBLY IAW AMM 36-11-01. NEW JOINT DUCT ASSEMBLY WAS NOT COMPLETE ORDERED NEW PARTS FOR ASSEMBLY AND INSTALLED PRESSURE TAP ASSEMBLY IAW AMM 36-11-01. REMOVED AND REPLACED PNEUMATIC OVERTEMP LIMITING SENSOR IAW AMM 36-11-13-004. PERFORMED IDLE LEAK CHECK- NO LEAKS. PERFORMED TAKE OFF POWER TEST #13, NO FAULTS AT THIS TIME. PERFORMED TAKE OFF POWER WITH BLEEDS ON AND NO FAULTS.