Service difficulty report · Pump · Airbus A319115

Difficulty date
June 15, 2019
Submitted
June 18, 2019
Operation
Air carrier
Aircraft
N3014R
Make and model
Airbus A319115
Aircraft serial
5842
Aircraft time
15,938 hours, 7,620 cycles
Part
Pump
Part number
4205401
Part serial
42054015664
Condition
Overheated
Location
Hyd System
Stage of operation
CL
How discovered
O
Nature of condition
M, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: PILOT RETURNED TO MIA ON ACCOUNT OF YELLOW HYDRAULIC SYSTEM ENGINE PUMP OVERHEAT. AN EMERGENCY WAS DECLARED AND THE FLIGHT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED #2 EDP CASE DRAIN FILTER AND FOUND CONTAMINATION IN THE DRAIN FILTER. MAINTENANCE REMOVED AND REPLACED THE #2 EDP IAW AMM 29-13-51. OPS CHECK GOOD. UPON REMOVAL, FOUND THE DRIVE SHAFT SHEARED AT THE ACCESSORY GEAR BOX.