Service difficulty report · Outflow Valve · Airbus A319112

Difficulty date
June 27, 2019
Submitted
June 28, 2019
Operation
Air carrier
Aircraft
N724UW
Make and model
Airbus A319112
Aircraft serial
1122
Aircraft time
53,614 hours, 32,159 cycles
Part
Outflow Valve
Part number
2079002AC
Part serial
9951792
Condition
Failed
Location
Cabin Pressure
Part time
50,077 hours, 30,166 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: PILOT REPORTS LEAVING 8000', LOST BOTH CABIN PRESSURIZATION SYSTEM. HAD TO GO TO MANUAL MODE TO CONTROL. MAINTENANCE REPLACED OUTFLOW VALVE IAW AMM 21-31-5. OPERATIONAL TEST OF THE PRESSURE CONTROL AND MONITORING NORMAL IAW AMM 21-31-00-710-002-A.