What was found
AIRCRAFT IN BASE VISIT: TRAPPED WATER INDICATION ON ELEVATOR HONEYCOMB CORE STRUCTURE LOWER SKIN PANEL LOCATED 86.0 INCH OUTBD FROM ELEVATOR RIB 5 AND 4 INCH FROM T/E. SIZE IS L=3 INCH X W=1.5 INCH APPROX. ON RH HORIZONTAL STABILIZER (1 EA), (L=3.52", W=1.56" TRAPPED WATER). REPAIRED RH HORIZONTAL STABILIZER (1EA) LOCATED LOWER SURFACE BTW RIB 8 TO RIB 9 146" I/B EDGE 5" FROM T/E ASPER A321 SRM 55-21-11-300-005 PARA 2A.