What was found
AIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS AFTER EMERGENCY LIGHT TEST WE FOUND AN EMERGENCY BATTERY INOP AT DOOR R4. REMOVED AND REPLACED BATTERY PACK POWER SUPPLY AT DOOR R4 IAW AMM 33-51-06. EMERGENCY LIGHT TEST CHECKED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS AFTER EMERGENCY LIGHT TEST WE FOUND AN EMERGENCY BATTERY INOP AT DOOR R4. REMOVED AND REPLACED BATTERY PACK POWER SUPPLY AT DOOR R4 IAW AMM 33-51-06. EMERGENCY LIGHT TEST CHECKED OK.