As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT IN BASE VISIT: MAINTENANCE REPORTS INTERIOR AND EXTERIOR EMERGENCY LIGHTS INOP AT 2L DOOR (AFT OF DOOR) RELAMPED BOTH, NO HELP. FOUND EMERGENCY POWER SUPPLY M33099 AT DOOR 2L FAULTY. REMOVED AND REPLACED EMERGENCY POWER SUPPLY PACT M33099 IAW AMM 33-51-06. OPS CHECK NORMAL.