Service difficulty report · Valve · Airbus A321231

Difficulty date
March 9, 2020
Submitted
March 12, 2020
Operation
Air carrier
Aircraft
N540UW
Make and model
Airbus A321231
Aircraft serial
4107
Aircraft time
34,156 hours, 13,371 cycles
Part
Valve
Part number
MS288892
Condition
Faulty
Location
L4 Door
Component
Assist Bottle · Ratier
Component part number
FE240007
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT GROUNDED - L4 DOOR DOES NOT SHOW ARMED ON CIDS PANEL, DID SHOW ARMED ON LOWER ECAM. FOUND DOOR ASSIST BOTTLE HAD LOW PRESSURE, DUE TO BAD FILLING VALVE. REPLACED FILLING VALVE AND O-RING PER AMM 52-10-00. SERVICED L4 DOOR ASSIST BOTTLE PER JOB CARD 26L80052001.