As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT IN BASE MAINTENANCE - EMERGENCY POWER SUPPLY UNIT (EPSU) INOPERATIVE, FORWARD GALLEY AREA, L1 DOOR AND R1 DOOR. REPLACED POWER SUPPLY UNIT AT L1 DOOR PER AMM 33-51-38-400-801-A. PERFORMED OPERATIONAL TEST PER AMM 33-51-00-710-801-A, CHECKED OKAY. [SEE ASSOCIATED REPORT AALA202004259006 FOR ADDITIONAL PART CHANGE.]