What was found
AIRCRAFT IN BASE MAINTENANCE - L4 DOOR EMERGENCY EXIT LIGHTS DO NOT COME ON WHEN COMMANDED. REMOVED AND REPLACED AFT CENTER EPSU (EMERGENCY POWER SUPPLY UNIT) 13WL PER AMM 33-51-38, AND JOB CARD 2827, OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE - L4 DOOR EMERGENCY EXIT LIGHTS DO NOT COME ON WHEN COMMANDED. REMOVED AND REPLACED AFT CENTER EPSU (EMERGENCY POWER SUPPLY UNIT) 13WL PER AMM 33-51-38, AND JOB CARD 2827, OPERATIONAL CHECK GOOD.