What was found
AIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR PANEL BREAK ASSEMBLY AT STA 540 BETWEEN BL 0 AND BL 24R, MEASURING L=1.0 IN. REPLACED BREAK WITH NEW IAW AARD 51-00-05-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR PANEL BREAK ASSEMBLY AT STA 540 BETWEEN BL 0 AND BL 24R, MEASURING L=1.0 IN. REPLACED BREAK WITH NEW IAW AARD 51-00-05-1.