What was found
AIRCRAFT WAS GROUNDED (SHORT TERM STORAGE): 2R DOOR EMERGENCY POWER ASSIST SYSTEM GREEN TEST LIGHT DID NOT COME ON WHEN EMERGENCY POWER ASSIST SYSTEM IS ARMED. REMOVED AND REPLACED DOOR 2R EMERGENCY POWER ASSIST SYSTEM BATTERY PACK ASSEMBLY (ALA202009139020) AND INSTALLED NEW EMERGENCY POWER ASSIST SYSTEM 9V BATTERIES (ALA202009139021) TO NEW DOOR 2R EMERGENCY POWER ASSIST SYSTEM BATTERY PACK ASSEMBLY, IAW AMM 52-10-00 AND TEST CHECKED GOOD.