AIRCRAFT WAS NOT GROUNDED. HYDRAULIC BLUE SYSTEM ELECTRIC PUMP LOW PRESSURE MESSAGE AFTER GEAR EXTENSION. CLEANED CANNON PLUG ON PRESSURE SWITCH 2151GN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK, PER AMM 29-32-10-00-00-02.