What was found
AIRCRAFT IN BASE MAINTENANCE. CORROSION OF INNER CHORD NEAR R2 DOOR SILL UNDER FLOOR PANEL AT STA 986.5 AND RBL 58, MEASURING L=3.8 IN, W=2.0 IN, D=0.025 IN. REPLACED INNER CHORD WITH NEW, IAW DRAWING 147A8501. SUPPLEMENTAL INFORMATION. INITIAL REPORT IDENTIFIED AS A LEVEL 2 FINDING IN ERROR, REPORT CORRECTED TO REFLECT PROPER LEVEL.