What was found
AIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON FLOOR BEAM AT FR 66 AND Y765 MEASURING 0.750 INCH BY 0.900 INCH BY 0.035 INCH. REMOVED AND REPLACED FLOOR BEAM, REF SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON FLOOR BEAM AT FR 66 AND Y765 MEASURING 0.750 INCH BY 0.900 INCH BY 0.035 INCH. REMOVED AND REPLACED FLOOR BEAM, REF SRM 51-72-11.