What was found
AIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON CENTER SHAPE FITTING BETWEEN FR 66 AND FR 68 AT STR 23L, MEASURING L=9.670 INCH, W= 0.500 INCH D=0.045 INCH. REPLACED CENTER FITTING, IAW SRM A321 51-72-11-911-001, 51-42-11-801 & DWG D53480505.