What was found
AIRCRAFT IN BASE MAINTENANCE. CORROSION OF RT SHORT FLOOR PANEL BETWEEN STA 847 AND STA 867 AT STR 15R AND WL 208.1, MEASURING L=2.0 IN, W=0.75 IN, D=0.008 IN. REPLACED FLOOR PANEL WITH NEW, IAW AARD 51-00-05-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE. CORROSION OF RT SHORT FLOOR PANEL BETWEEN STA 847 AND STA 867 AT STR 15R AND WL 208.1, MEASURING L=2.0 IN, W=0.75 IN, D=0.008 IN. REPLACED FLOOR PANEL WITH NEW, IAW AARD 51-00-05-1.