Service difficulty report · Smoke Detector · Airbus A321211

Difficulty date
January 18, 2021
Submitted
January 19, 2021
Operation
Air carrier
Aircraft
N162UW
Make and model
Airbus A321211
Aircraft serial
1412
Aircraft time
64,645 hours, 24,233 cycles
Part
Smoke Detector
Condition
False Indication
Location
Lavatory
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS NOT GROUNDED. CLASS 1 WARNING LAVATORY SMOKE, WENT AWAY AFTER 30 SECONDS. FLIGHT ATTENDANT REPORT RIGHT AFT LAVATORY WARNING CAME ON. NO EVIDENCE OF SMOKE. PERFORMED OPERATIONAL TEST OF LAVATORY SMOKE DETECTION, IAW AMM 26-17-00. OKAY FOR SERVICE.