What was found
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA ON FLOOR PANEL 222CF L=27 IN W=25 IN. R & R FLOOR PANEL 222CF PER SRM 53-12-00-300-006.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA ON FLOOR PANEL 222CF L=27 IN W=25 IN. R & R FLOOR PANEL 222CF PER SRM 53-12-00-300-006.