What was found
AIRCRAFT IN BASE MAINTENANCE: FOUND DELAMINATED AREA ON FLOOR PANEL221PF FROM FR12 TO FR16 AND Y1292 TO Y765, MEASURING L= 41 INCHES W= 13 INCHES. REPLACED FLOOR PANEL REF A319 SRM 53-02-00-300-011 AND IRM 9701 REV I.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: FOUND DELAMINATED AREA ON FLOOR PANEL221PF FROM FR12 TO FR16 AND Y1292 TO Y765, MEASURING L= 41 INCHES W= 13 INCHES. REPLACED FLOOR PANEL REF A319 SRM 53-02-00-300-011 AND IRM 9701 REV I.