What was found
AIRCRAFT IN BASE MAINTENANCE: CRACK IN FUSELAGE SKIN FROM CONTACT WITH APU DOOR HINGE ARMS BETWEEN STA 1101 AND STA 1149 AT STR 20R, MEASURING L=0.5 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 53-80-01-2R-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: CRACK IN FUSELAGE SKIN FROM CONTACT WITH APU DOOR HINGE ARMS BETWEEN STA 1101 AND STA 1149 AT STR 20R, MEASURING L=0.5 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 53-80-01-2R-1.