What was found
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED/DISBONDED AREA FOUND ON FLOOR PANEL 251FF, L= 8 IN, W = 3.5 IN. REMOVED AND REPLACED FLOOR PANEL 251FF PER SRM 53-02-00-300-011.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED/DISBONDED AREA FOUND ON FLOOR PANEL 251FF, L= 8 IN, W = 3.5 IN. REMOVED AND REPLACED FLOOR PANEL 251FF PER SRM 53-02-00-300-011.