What was found
AIRCRAFT IN BASE MAINTENANCE: CORRODED AREA FOUND ON CENTER FITTING LOCATED AT STR 23L FROM FR66 TO FR 68 AT AFT GALLEY AREA. L= 1.36 INCHES, W= 0.347 INCHES, D= 0.076 INCHES. REPLACED CENTER FITTING LOCATED AT STR 23L FROM FR66 TO FR 68 AT AFT GALLEY AREA PER SRM 51-42-11-801, AND SRM 51-72-11-911-001.