What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT GALLEY AREA FLOOR BEAM LOCATED AT Y1162 BETWEEN FR68 TO FR69. REPLACED BEAM PER SRM 51-42-11-801.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT GALLEY AREA FLOOR BEAM LOCATED AT Y1162 BETWEEN FR68 TO FR69. REPLACED BEAM PER SRM 51-42-11-801.