What was found
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA FOUND ON FLOOR PANEL 252TF LOCATED AT STA FR59, BUTT LINE -Y765. L= 21 INCHES, W= 7.5 INCHES. REPLACED FLOOR PANEL LOCATED AT STA FR59, BUTT LINE -Y765 PER SRM 53-02-00-300-011.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA FOUND ON FLOOR PANEL 252TF LOCATED AT STA FR59, BUTT LINE -Y765. L= 21 INCHES, W= 7.5 INCHES. REPLACED FLOOR PANEL LOCATED AT STA FR59, BUTT LINE -Y765 PER SRM 53-02-00-300-011.