What was found
AIRCRAFT IN BASE MAINTENANCE: FOUND CORRODED AREA MEASURING 1.5 INCH DIAMETER BY 0.058 INCH DEEP ON FLOOR BEAM AT STR 23L, -Z500 AND Y765. REMOVED AND REPLACED FLOOR BEAM REF SRM 51-72-11 AND SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: FOUND CORRODED AREA MEASURING 1.5 INCH DIAMETER BY 0.058 INCH DEEP ON FLOOR BEAM AT STR 23L, -Z500 AND Y765. REMOVED AND REPLACED FLOOR BEAM REF SRM 51-72-11 AND SRM 51-42-11.