What was found
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION FOUND ON FLOOR PANEL 241JF LOCATED AT STA FR 42 TO FR 44, BUTT LINE -Y254 TO Y254. L= 39 INCHES, W= 8 INCHES. REPLACED FLOOR PANEL 241JF PER SRM 53-02-00-300-011.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION FOUND ON FLOOR PANEL 241JF LOCATED AT STA FR 42 TO FR 44, BUTT LINE -Y254 TO Y254. L= 39 INCHES, W= 8 INCHES. REPLACED FLOOR PANEL 241JF PER SRM 53-02-00-300-011.